CentriPro Alarms

TAN3M (XT Alarm System)

• The Tank Alert® XT can be used as a high level alarm in lift chambers, sump pump basins and holding tanks.
• UL Listed (for indoor and outdoor use) and CSA Certified.
• Voltage: 120 VAC, 50/60 Hz, 8.5 watts maximum, (alarm condition)
• Enclosure meets Type 3R water-tight standards, listed for indoor or outdoor use under UL standard 864. Dimensions are 6.5” x 4.5” x 3.0”
• Premounted terminal block so enclosure can also be used as a junction box for splicing pump, pump switch and pump power. Meets NEC standard for junction boxes.
• N.O. float switch has a 15’ long, 18 gauge, 2 conductor SJOW (UL) cord
• Mechanical SignalMaster® Float on TAN3M, switches are rated for a maximum fluid temperature of 140º F (60º C)
• Automatic alarm reset, alarm test switch and horn silence switch
• Alarm Horn: 85 decibels at 10 feet (3 meters)
• Does not control or interface with pump
• Operates even if pump circuit fails when wired on separate circuit
• No power cord.

General Selection Tools:

Recommended Browsers: IE10 or Google Chrome

Report Bugs/Request Enhancements
Please email the following address to report issues and request enhancements: ebusiness.support@xyleminc.com